startTime=0 stopTime=350 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.14 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Thermal.HeatConduction.ScaledExperiments.OneDHeatTransferTT_FD_N_640 -abortSlowSimulation -alarm=300 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.012886s reading init.xml | | | | | | 0.00183735s reading info.xml | | | | | | 0.00025566s [ 0.1%] pre-initialization | | | | | | 0.000295324s [ 0.1%] initialization | | | | | | 3.8122e-05s [ 0.0%] steps | | | | | | 0.0985734s [ 32.9%] solver (excl. callbacks) | | | | | | 0.0108471s [ 3.6%] creating output-file | | | | | | 0.000499609s [ 0.2%] event-handling | | | | | | 0.00158576s [ 0.5%] overhead | | | | | | 0.187415s [ 62.6%] simulation | | | | | | 0.29951s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 209 steps taken | | | | | | 238 calls of functionODE | | | | | | 27 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00230141s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.